KP1060C000-G0A

KP1060C000-G0A

KP1000 series is a 96x96mm digital program controller with the indicating accuracy of ±0.1%, the control cycle of approximately 0.1 seconds and maximum 19 program patterns (maximum 19 steps/pattern). 

Various functions including the whole program pattern display screen and universal input are provided as standard.

Product Details

Input signal

Universal input

Control mode (Output No.1)

Voltage Output Type

Control mode (Output No.2)

None

Communications interface

Transmission signal output

External drive input

Panel sealing and terminal cover

Case color

Gray

Power supply voltage

100-240V (AC)

Features

  • Large easy to view 5-digit display
  • Outstanding controllability
  • Operability inheriting previous models
  • High precision transmission signal output
  • 24V power supply voltage type provided
  • Program pattern
  • Easily identifiable pattern progress display
  • Universal input
  • 2 colors of casing available
  • Conforming to international safety standards and European directives (CE)
  • Conforming to ROHS

Specifications

  • Input Signal: Thermocouple: B, R, S, K, E, J, T etc., DC voltage: ±10mV, ±20mV, ±50mV, ±100mV, ±5V, ±10V, DC current: 20mA, Resistance thermometer: Pt100, JPt100 etc.
  • Accuracy Rating: ±0.1%±1digit of input span
  • Reference Junction Compensation
    Accuracy:
    K, E, J, T, N, Platinel II・・・±0.5°C or ±20μV equivalent value whichever greater Others・・・±1.0°C or ±40μV equivalent value whichever greater
  • Sampling Cycle: Approx. 0.1sec.
  • Burnout: High limit burn out is standard provision for thermocouple, DC voltage (±50mV or lower), and resistance thermometer (3-wire). At burnout, output value of Output 1/ Output 2 can be set freely
  • Display Element: Upper display LED Lower display LCD (with backlight) 108×24 dots
  • Rated Power Supply Voltage: General specifications 100 to 240V AC, 24V power supply specifications 24VAC/24VDC
  • Weight: Without option, Approx. 450g with option, Approx. 580g
  • Output Type: Current output type, ON-OFF pulse type, voltage output type, SSR drive pulse type, ON-OFF servo type
  • Controller Set Value: PID 8types, P:0 to 999.9% (If it is 0, it acts as 2-position control type), I:0 to 9999 sec. (If it is 0, no integral action), D:0 to 9999sec., High limit・・・0.0 to 100.0%, Low limit・・・-100.0 to 0.0%
  • ON-OFF Pulse Type: Output signal: ON-OFF pulse
    continuity signal Contact capacity: Resistance
    load 100 to 240VAC 30VDC, 5A or lower, Inductive load 100 to 240VAC 30VDC, 2.5A
    or lower, Minimum load 5VDC 10mA or lower
  • ON-OFF Servo Type: Output signal: ON-OFF servo continuity signal, Contact capacity: Resistance load 100 to 240VAC 30VDC, 5A or lower, Inductive load 100 to 240VAC 30VDC, 2.5A
    or lower, Minimum load 5VDC 10mA or higher
  • Current Output Type: Output signal: 4 to 20mA DC, Load resistance: 750Ωor lower
  • SSR Drive Pulse Type: Output signal:   ON-OFF pulse voltage signal, Output voltage: ON voltage 12VDC±20% OFF voltage 0.8VDC or lower
  • Voltage Output Type: Output signal: 0 to 10V, Output impedance: Approx. 10Ω, Load resistance: 50kΩor higher
  • Alarm Point: 4 points

Setting Unit

  • Output Signal: Analog output 4 to 20mADC, 0 to 1VDC, 0 to 10VDC Digital output RS-422A, RS-485
  • Output Update Cycle: Analog output 0.1sec.
  • Digital output: Approx. 1sec.
  • Accuracy Rating: ±0.1% of span
  • Resolution: Approx. 1/30000
  • Output Impedance: Approx.10Ω
  • Load Current: Current output 400Ω or lower, Voltage output 50kΩ or higher