IR-FAQINN (300 to 1200 C)

IR-FAQINN (300 to 1200 C)

Infrared Thermometer (Fiber Type) 

IR-FA series is an optical fiber transmission type radiation thermometer. Measurement light (radiant energy) captured by a size of a pinky, small lens assembly is led to a detecting element stored in a small box type thermometer. With small lens assembly and flexible optical fiber transmission, this thermometer is useful for measurements of a place where direct view is impossible or a narrow place, and a place where inductive interference occurs electrically.

Product Details

Type

Two-color type (300 to 1200 °C)

Element

In GaAs

Detecting Element

In GaAs/ In GaAs

*Fiber 2m (Model:IR-FL5NN02) is sold separately



Features

  • Optical fiber can be used without cooling up to 150°C.
  • Optical fiber does not have electrical conduction so it is applicable for induction heating and explosion proof atmosphere.
  • Laser targeting option is available for checking measuring point.
  • Thermometer is compact, light weight, and DIN rail installation available.
  • For low temperature, for medium to high temperature, and two-color type etc. various types are available.

Specifications

Thermometer

Measuring System: Two-color type

Detecting Elements: InGaAs/InGaAs

Measuring Wavelength: 1.55/1.35μm

Accuracy Rating: Below 1000°C: ±5°C

1000°C or more, below 1500°C: ±0.5% of
measured value

1500°C or more, below 2000°C: ±1% of
measured value

2000°C or more: ±2% of measured value

Repeatability: 0.2°C

Temperature Drift: 0.2°C/°C or 0.02%/°C of measured value, whichever larger

Resolution: 1.0°C

Response Time: 0.04s

Emissivity (Ratio) Compensation: Emissivity set value (ratio): 1.999 to 0.050

Signal Modulation: DELAY: Average value tracing (smoothing) (Modulation degree 0.0 to 99.9s, 0.1s step can be set freely), Modulation degree 0=REAL, PEAK: Max. value tracing (Modulation degree 0, 2, 5, 10°C/s selection), Modulation degree 0=Peak hold)

Display System: LCD 4-digit (Temperature display, parameter display)

Analog Output: 4 to 20mA DC Isolated output (Load resistance 500Ω or lower)

Accuracy rating: ±0.2% of output range

Output resolution: 0.01% of output range

Output scaling: It can be set freely within the measuring temperature range.

Dummy output: It can be set freely within the range of 0 to 100% of analog output.

Contact Output: 1-point, high (low) alarm or error signal, Photo-coupler 30V DC, Max. 50mA

Contact Input: 1-point, peak hold or sample hold, dry contact, or open collector

Parameter Settings by Keys: Operator mode: Setting of emissivity, signal modulation, alarm and others

Engineering mode: Setting of output scaling, ZERO/SPAN, automatic emissivity calculation: input of reference temperature, output correction and others including option-related-parameters

Calculation Function: ZERO/SPAN adjustment, Automatic emissivity calculation, Output correction

Self-Diagnosis: Thermometer temperature abnormal, parameter error

Option: Laser Targeting: Built-in semi-conductor laser floodlight, laser beam 1mW or less (645nm) class 2, (Built-in semi-conductor laser floodlight is not available for High-sensitivity type)

Analog Input: Input signal: 4 to 20mADC Select remote emissivity programming or automatic emissivity calculation input of reference temperature.

Communication Interface: RS-485 Sending of measured data (up to 1-digit below decimal point), and sending/receiving of parameters

Working Temperature Range: 0 to 50°C

Rated Power Supply Voltage: 24V DC (allowable voltage fluctuation range to 28V DC)

Power Consumption: Max. 3VA (Approx. 130mA)

Connection: Cramp type no-screw terminals

Installation Method: DIN-rail installation or wall installation

Case/Material: Resin

External Dimensions/Weight: W90×H90×D60mm, Approx. 250g (Thermometer only)

CE Marking Conformity: Conforms to CE marking (EMC directive: EN5501 Group 1 Class A, EN50082-2)