AH4706-N0A-NNN (6 inputs)
AH4706-N0A-NNN (6 inputs)
AH4000 Series Hybrid Memory Recorder (180mm Chart paper)
AH4000 series is a hybrid recorder which employs bright and clear, easy to view LCD display. Measuring value display is prepared as 1 point display, multi-points simultaneous display and digital display + bar graph display. Various measuring and recording settings can be easily done by front key switch and confirmed by LCD digital display.
Product Details |
|
Type |
Multi-point type |
Panel size |
288x288 mm. |
Chart paper |
180mm |
Input point |
6 points |
Communication interface |
None |
Alarm output |
None |
Power supply |
100-240V AC |
Carrying handle and feet (option) |
None |
For OP/SP |
None |
Features
Features
- Equipped with SD card (sold separately) and it can record data, read and write setting value.
- Equipped with DC voltage 10 kinds, T/C 36 kinds, RTD 12 kinds, in total 58 kinds. Easily set the range per channels.
- Provided with USB port and connect with PC directly. RS232C, RS422A, RS485 and Ethernet communication interface is optionally prepared. When Ethernet is selected, settings from the web and E-mail alarm notification are added.
- By Data acquisition software, the use of application expands from recording/ management to information processing. *Optional communication interface required. Data analysis software can replay display, wave form process, editing and trend display. Parameter setting software can manage the setting information on PC.
- Set 4 types of alarm per each input points. When alarm occurs, status display “ALM” flashes and measuring value flashes at LCD operation screen.
- Can set the alarm operation when chart end is detected.
- Process the measured data by programming setting and displayed/ recorded data of each channels are shown as programmed result data.
Specifications
Specifications
Measuring points: Multi-point type 6,12,24 points
Input types:
DC voltage: ±13.8mV, ±27.6mV, ±69.0mV, ±200mV, ±500mV, ±1V ±5V, ±10V, ±20V, ±50V
DC current: Max 50mA by external shunt resistor (100Ω, 250Ω) (sold separately)
Thermocouple: K, E, J, T, R, S, B, N, U, L, W -WRe26, WRe5-WRe26, PtRh40-PtRh20, NiMo-Ni, CR-AuFe, Platinel, Au/Pt
Resistance thermometer: Pt100, old Pt100, JPt100, Pt50, Pt-Co
Accuracy ratings: ±0.1% of measuring range ±1digit (DC voltage input)
Measuring interval: Multi-point type 1 second / 6 points, 2 seconds/ 12 points,2 seconds/ 24 points
Recording method: Multi-point type Wire-dot type 6-color ribbon
Digital printing: dot type plotter pen
Chart paper: Fan-fold type, Total width 114mm, total length 10m, effective chart width 100mm
Chart speed: Multi-point type 1 to 1500mm / h, in 1mm/h increments (12.5mm / h can be set exceptionally)
Alarm types: Absolute alarm, differential alarm, rate-of-change alarm, FAIL, calendar timer, chart end.
Alarm settings: Individual settings, Max 4 levels/channel
Rated power voltage: 100 to 240VAC, 50/60Hz
Dimensions: Multi-point type W288×H288×D195mm
Weight: About 7.6kg