Skip to product information
1 of 1

DP2000G Graphic Program Controller

DP2000G Graphic Program Controller

Regular price 0.00 ฿
Regular price Sale price 0.00 ฿
Sale Sold out
Request for Quotation

Graphic Program Controller/Setter DP-G Series

The DP2000G is a graphic programmable controller for wide-area control that divides control range into two, low and high ranges, and automatically switches at the range switching point.

Regulation Mode (Output 1)

Model No.

ON-OFF pulse type

DP2110G000-G10

ON-OFF servo type (standard load specification)

DP2120G000-G10

Current output type

DP2130G000-G10

SSR drive pulse type

DP2150G000-G10

Voltage output type (general type)

DP2160G000-G10

ON-OFF servo type (minute load specification)

DP2180G000-G10

Current output type (high accuracy type)
4 mA to 20 mA DC

DP21A0G000-G10

Current output type (high accuracy type)
1 mA to 5 mA DC

DP21B0G000-G10

Voltage output type (high accuracy type)
0 V to 10 V DC

DP21C0G000-G10

Features

Graphic program controller for wide-area control with a large 5.6-inch color LCD display

  • The DP2000G is a graphic program controller for wide-area control that divides control range into two, low and high ranges, and automatically switches at the range switching point. By using the optimal sensor for each range, it is possible to perform precise and stable control from low to high ranges. control range switching is performed automatically and bumplessly, allowing for smooth switching without disturbance.
  • The easy-to-read color LCD display various data such as program pattern in an easy-to-understand manner.
  • In addition to the all-at-once display, various monitor display screens are available, including enlarged numeric display, bar graph display, and trend display.
  • Easy to use with Japanese setting menu
  • 28 contact outputs, 16 contact inputs, analog transmission output (option), and communication interface (option) are available, making system construction easy.
  • Parameter editing software for PC is included as standard.

Specifications

Controller specification

  • Input points: 2 points (Rang-R, Rang-H)
  • Input signal: Thermocouple: B, R, S, K, E, J, T, etc.
  • DC voltage: ±10 mV, ±20 mV, ±50 mV, ±100 mV, ±5 V, ±10 V
  • DC current: 20 mA
  • Resistance thermometer: Pt100, JPt100, etc.
  • Accuracy rating:  ±0.1%
    of input span ±1 digit (under standard operating conditions) * There are separate detailed rating descriptions.
  • Reference junction compensation accuracy: K, E, J, T, N, Platinel II: ±0.5°C or lower
  • Other than above: ±1.0°C or lower
  • Sampling rate: Approx. 0.1 second
  • Burnout: Burnout is provided as standard for thermocouple, DC voltage (±50 mV or less) and resistance thermometer.
  • Rated power supply voltage: 100 V to 240 V AC 50/60 Hz (universal power supply)
  • Weight: Approx. 1.7 kg
  • Output format: Current output type, ON-OFF pulse type, Voltage output type, SSR drive pulse type
  • Adjustment setting value: PID 8 types
  • P: 0% to 999.9% (0 for 2 position operation)
  • I: 0 to 9999 seconds (0 is equivalent to infinity)
  • D: 0 to 9999 seconds
  • ON-OFF pulse type: Output signal: ON-OFF pulse conductive signal
  • Contact capacity: Resistive load 100 V to 240 V AC 30 V DC, 5 A or less Inductive load 100 V to 240 V AC 30 V DC, 2.5 A or less
  • ON-OFF servo type:       
  • Output signal: ON-OFF servo conductive signal
  • Contact capacity: Standard load specification:
  • Resistive load 100 V to 240 V AC 30 V DC, 5 A or less
  • Inductive load 100 V to 240 V AC 30 V DC, 2.5 A or less
  • Minute load specification:
  • Resistive load 100 V to 240 V AC 30 V DC, 20 mA or less
  • Inductive load 100 V to 240 V AC 30 V DC, 20 mA or less
  • Current output type: Output signal: 4 mA to 20 mA DC or 1 mA to 5 mA
  • Load resistance: 750 Ω or less
  • SSR drive pulse type: Output signal: ON-OFF pulse voltage signal         
  • Output voltage: ON voltage 12 V DC ±20%, OFF voltage 0.8 V DC or lower
  • Output signal: Output signal 0 V to 10 V
  • Output impedance: Approx. 10 Ω
  • Number of alarm points: 4 points + 4 points (extended allocation setting)

Specifications Sheet Download