Infrared Multi Analyzer - IRMA2100S With Liquid Cell
Infrared Multi Analyzer - IRMA2100S With Liquid Cell
IRMA2100S – Infrared Moisture Meter (For Liquids, Fiber Type)
The IRMA2100S (Liquid type) is designed for general-purpose liquid applications, combining the advantages of fiber optics with reliable infrared reflection measurement for real-time inline monitoring.
Product Details |
|
Model |
IRMA2100S |
Type |
General moisture (Fiber Type) |
Measurement distance/diameter |
15 mm /Φ20 mm - 50 mm /Φ50 mm |
Response time |
28 msec |
Output / Communication |
RS-485 (standard) |
Explosion-proof |
Exd II BT5 |
Applications:
- Measurement of moisture concentration in a cleaning solution
- Measurement of resist stripping solution concentration
Software Package:
- Dedicated software for Windows 10 is included, providing seamless data management and analysis.
- The software allows users to display profiles, save data, convert files to CSV format, manage product types, and create calibration curves.
- Up to 3 detectors can be connected to single PC.
特長
特長
- Up to 10 wavelengths, capable of measuring 4 constituents such as; moisture, film-thickness, organism and coating-thicknessin real time simultaneously.
- Connectivity to multiple interfaces, RS485 (MODBUS), Ethernet (LAN)
- High-speed & High-repeatability (28ms)
- Multi-calculation function
- Self-diagnostic function, easy maintenance.
- Conforms to CE standards
仕様
仕様
Measuring method: Infrared absorption type
Measuring wavelengths: Up to 10 wavelengths
Measuring component: Up to 4 constituents
Light source: Tungsten lamp
Measurement distance/diameter (Fiber type):
Without lens: Φ 20/15mm to Φ 40/50mm, With lens: Φ 20/25mm to Φ 40/100mm
Fiber length:
Standard 1.5m, Max.5m (Reflection type fiber), Standard 2m, Max.10m (Transmission type fiber)
Fiber protection: Stainless steel flexible armor
Minimum bending radius: R100mm
Working temperature: 0 to 150°C
Purge air flow: With lens --- Air purge disabled, Without lens --- 5 to 20L/min
Accessory: Vertical mounting holder Flange holder
Analog output: 4 to 20mA DC, ±0.2% FS (load resistance 500Ω or less)
Communications: RS-485 (MODBUS)
Output renewal cycle: 28ms
Display /Settings: Display data & setup parameter
Parameters are configurable by key
Calibration curve: Linear, quadratic, cubic & multiple regression line
Calibration curve correction: Linear & quadratic correction
Number of calibration curve: 99 (maximum)
Computation Function: 2-color, 3-color ratio computation, multiple regression computation
Color density computation (moisture /thickness (color density meter only)
Smoothing (delay): 0 to 9.9 seconds, 10 to 99 seconds (can selectable)
Calibration: By checking plate
Self-diagnostic function: When self-diagnostic abnormality occurs, contact and communication output
Correction input function: External 4 to 20mA DC (1 input) corrects measurement data (sample temperature correction, etc.)
Contact Input/Output: Contact input (Di) preset, data hold, real/smooth switching can be selected by contact input.
contact output (Do) outputs the selected function, either self-diagnostic function (1b) or higher and lower limit alarm (1a)
Power supply: 24V DC (supplied from power supply unit IR-WEP. Power supply unit: 100-240V AC, 47 450Hz)
Power consumption: Approx. 30VA
Connection: Terminal connection
Case: Aluminum castings
Weight: Approx 4.3kg
Installation Method: Bolt suspension method with 4 pieces of M8 bolts
CE marking: CE marking compliant, EMC directive
EN61326+A