Infrared Multi Analyzer - IRMA1200S
Infrared Multi Analyzer - IRMA1200S
IRMA1200S – Infrared Moisture Meter (High Moisture, Mirror Type)
The IRMA1200S is designed for high-moisture applications, using the infrared reflection (mirror type) method. It provides accurate, real-time, and stable measurement even in environments where moisture content is relatively high.
Product Details | |
Model | IRMA1200S |
Type | High moisture (Mirror Type) |
Measuring range | 10–70% H₂O |
Number of wavelengths | 3 bands |
Measurement distance/diameter | 300 mm ±100 mm / 50 mmΦ |
Response time | 28 msec |
Output / Communication | RS-485 (standard) |
Explosion-proof | Exd II BT5 |
Applications:
Ideal for a wide range of moisture measurement applications, including:
- Powders (e.g., chemicals, food ingredients)
- Fibers (e.g., paper, textiles)
- Particulates (e.g., wood chips, soil, RDF)
- Liquids (e.g., solutions, slurries)
Software Package:
- Dedicated software for Windows 10 is included, providing seamless data management and analysis.
- The software allows users to display profiles, save data, convert files to CSV format, manage product types, and create calibration curves.
- Up to 3 detectors can be connected to single PC.
特長
特長
- Up to 10 wavelengths, capable of measuring 4 constituents such as; moisture, film-thickness, organism and coating-thicknessin real time simultaneously.
- Connectivity to multiple interfaces, RS485 (MODBUS), Ethernet (LAN)
- High-speed & High-repeatability (28ms)
- Multi-calculation function
- Self-diagnostic function, easy maintenance.
- Conforms to CE standards
仕様
仕様
Measuring method: Infrared absorption type
Measuring wavelengths: Up to 10 wavelengths
Measuring component: Up to 4 constituents
Light source: Tungsten lamp
Measurement distance/diameter (Mirror type): 200 to 400 mm, 50 x 50 mm□
Analog output: 4 to 20mA DC, ±0.2% FS (load resistance 500Ω or less)
Communications: RS-485 (MODBUS)
Output renewal cycle: 28ms
Display /Settings: Display data & setup parameter Parameters are configurable by key
Calibration curve: Linear, quadratic, cubic & multiple regression line
Calibration curve correction: Linear & quadratic correction
Number of calibration curve: 99 (maximum)
Computation Function: 2-color, 3-color ratio computation, multiple regression computation
Color density computation (moisture /thickness (color density meter only)
Smoothing (delay): 0 to 9.9 seconds, 10 to 99 seconds (can selectable)
Calibration: By checking plate
Self-diagnostic function: When self-diagnostic abnormality occurs, contact and communication output
Correction input function: External 4 to 20mA DC (1 input) corrects measurement data (sample temperature correction, etc.)
Contact Input/Output: Contact input (Di) preset,
data hold, real/smooth switching can be selected by contact input.
contact output (Do) outputs the selected function, either self-diagnostic function (1b) or higher and lower limit alarm (1a)
Operating temperature limit: 0 to 50°C (air cooling required for temperatures above 45°C. However, the air must be dry instrument air with a temperature of approximately 30°C or less.)
Power supply: 24V DC (supplied from power supply unit IR-WEP. Power supply unit: 100-240V AC, 47 450Hz)
Power consumption: Approx. 30VA
Connection: Terminal connection
Case: Aluminum castings
Weight : Approx 4.3kg
Installation Method: Bolt suspension method with 4 pieces of M8 bolts
CE marking: CE marking compliant, EMC directive EN61326+A